Có gì mới trong 0.19.0
WinMedic v0.19.0
A friendlier start. A first start opens with a short introduction, Settings
comes in five pages, and WinMedic can share anonymous usage data, but only
if you agree. A scan now waits for the component store analysis to finish
instead of dropping it, and its bar keeps moving while it does.
New
- An introduction on the first start: three short pages before the
window itself: what WinMedic does, the two buttons that do it (Scan now,
then Repair), and what you can leave alone (Advanced mode, Settings).
Skip is as big as Next. Esc skips, and Enter and the arrow keys
read on and back. Help -> Show the introduction shows the same pages at
any time.
- Settings, one page at a time: the Settings view is five short pages
now, picked from a list on the left: Repairs, Undo changes, Scans,
Logs and General. A page shows only a handful of settings, so the
small window of Easy mode is no longer filled with small print. Each
setting has one line of explanation. The arrow keys walk the settings and
turn the page with them, PgUp and PgDn turn the pages, and B goes to
the registry backups and back. The page you pick comes in the way the two
views do.
- Anonymous usage data, only if you agree: after the introduction of a
first start, WinMedic asks once whether to share it. It stays off until
you click Yes, share. Esc counts as No, thanks, and no other key
answers. With it on, the window sends a short report after each finished
scan and after each repair that repaired or failed at something: the
WinMedic version, the Windows build number, Easy or Advanced mode, how
long the scan took, the health score, and for each check only counts
(found, repaired, failed). It never sends names of devices, files or
folders, your user or computer name, or the text of a finding.
- Where to see it: Settings -> General -> Share anonymous usage data.
Ticking it opens the page that says what is sent and where it goes, and
Show what is sent shows a report before anything goes out. Unticking it
takes effect at once. Every report that was sent is also written to
usage-data.log in the log folder.
- Where it goes: to the developer's own server in Germany, by way of
Cloudflare. No analytics company is in between. Like every server, both
see your IP address. The developer's server does not write it down and
does not pass it on to the statistics.
- A long scan says that all is well: after 30 seconds, Easy mode's scan
page says "All good, WinMedic is still checking. The last checks take the
longest." under Cancel. Below that line it names the checks still
running when one or two are left, such as "Still running: System & Cache
Cleaner.", and how many are left otherwise.
- The component store is checked to the end: a scan gave the analysis
of the component store two minutes. On a PC where it takes longer, the
scan dropped it without a word and could miss what the cleanup would
free. The analysis now gets up to 15 minutes. When it still does not
finish, the scan says "Component store not checked" and gives the reason
in the scan log.
- A bar that keeps moving: a scan used to reach 99 % within seconds and
then wait there for the component store analysis. WinMedic now remembers
how long the last analysis took and moves the bar by the clock. The step
says how long it took last time, for example "took 4m 52s last time".
- Keys on the buttons: a button that has a key now shows it as a small
key cap after its label, for example Scan now S, Repair F,
Cancel Esc and Export report E. Until now the key was in a
tooltip, which only appeared when you rested the pointer on the button. The
mode button no longer has "(F7)" in its label.
- Easy mode points to Advanced mode once: the lines below the buttons
say only what happened, such as "1 repair did not work.", "1 more needs
your decision." or "Could not check X.". One link below them, "Show
details in Advanced mode (F7)", replaces the pointer each line used to
carry.
Good to know
- Nobody who already uses WinMedic is asked about usage data, and
nobody is asked twice. For everyone but a first start, the switch under
Settings -> General stays off until you tick it.
- --scan, --auto-fix, the background scan and a simulation send
nothing, whatever the switch says.
- The introduction opens by itself only on a first start: on a PC with
no WinMedic settings and no saved scan. An update does not show it.
Help has it for everyone else.
- A scan can take longer now on a PC with a slow component store
analysis. It takes as long as the analysis does, about five minutes on
the developer's PC. Easy mode still says a scan takes a minute or two. A
scan can be cancelled as before.
- The bar is an estimate: it counts with the time the last analysis
took, or with two minutes if there was none yet. When the analysis takes
longer than last time, the bar waits until it is done.
- A key cap shows only where the key does what the button does:
Update now has none in Settings, where U restores a snapshot, and
Cancel has none while a filter is set, because Esc clears the filter
first.
- With "Animation effects" switched off in Windows, the pages of
Settings do not move, as with the rest of the window.
- If you tried a preview of this version, WinMedic offers you this
release as an update, as usual.
Full changelog: v0.18.0...v0.19.0